MIL-PRF-27/339E
Regulation: Voltage (no load ) Voltage (rated load )
x 100
Voltage (rated load )
Shall not exceed 10 percent.
Polarity: Additive with terminals 2 and 3 connected.
Marking location: See figure 1.
Part or Identifying Number (PIN): M27/339-(dash number from table I).
TABLE I. Electrical ratings.
Secondary
Secondary
Secondary
current
DCR
Dash
voltage
(3-5)
(3-5)
number
(3-5)
(ohms) 25%
(V rms) 5%
(amperes)
M27/339
(CT)
-01
5.0
1.2
173
-02
6.3
.95
24
-03
8.0
.75
396
-04
10.0
.60
587
-05
12.6
.475
99
-06
14.0
.428
1.11
-07
16.0
.375
1.58
-08
18.0
.333
2.21
2.78
.300
20.0
-09
2.8
.273
22.0
-10
3.6
.240
25.0
-11
4.2
.214
28.0
-12
5.71
.192
-13
31.0
6.89
.171
-14
35.0
9.39
.154
-15
39.0
10.25
.139
-16
43.0
15.30
.125
-17
48.0
17.30
.109
-18
55.0
24.9
.095
-19
63.0
27.1
.085
-20
70.0
39.0
.075
-21
80.0
41.0
.067
-22
90.0
59.5
.060
-23
100.0
68.5
.054
110.0
-24
.048
96.0
123.0
-25
133.0
.043
138.0
-26
153.0
.038
157.0
-27
168.0
.034
175.0
-28
248.0
.030
200.0
-29
278.0
.027
220.0
-30
3.74
.231
26.0
-31
65.10
.052
115.0
-32
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business