MIL-PRF-27/45C
REQUIREMENTS: (When numbers in parentheses, such as (1-2) are used, they indicate the winding and
the extreme terminals of the winding.)
Electrical ratings: See table I.
Primary voltage (1-2): 115 volts ±10 percent, 400 Hz ±5 percent.
Design and construction:
Dimensions and configuration: See figure 1.
Weight: 3.4 ounces, maximum.
Duty cycle: Continuous.
Case: Plastic encapsulated.
Material: Plastic.
Altitude: 70,000 feet, maximum.
Operating temperature range: -55°C to +130°C.
Terminals: Printed circuit pins - tinned brass.
Terminal strength: MIL-STD-202, method 211, test condition A, 2 pounds.
Dielectric withstanding voltage:
At sea level: 2.8 times the maximum working voltage specified in table I.
At reduced barometric pressure: 1.25 times the maximum working voltage specified in table I.
Electrical characteristics:
No load: With 115 volts rms, 400 Hz across (1-2): Current in (1-2) shall not exceed 16 mA rms.
Rated load: With 115 volts, 400 Hz across (1-2) and a restrictive load with current as specified in
table I in (3-5), the voltage across (3-5) shall be as specified in table I.
Efficiency: 87 percent minimum at rated load.
Electrostatic shielding: The voltage ratio shall be a minimum of 5 to 1 at 20 kHz.
Polarity: Additive with terminals 2 and 3 connected.
Regulation: Voltage (no Load) - Voltage (rated load) x 100
Voltage (rated load)
shall not exceed 8 percent.
Phase shift: 1.0 electrical degree between primary and secondary voltage at rated load, maximum.
Temperature rise: 32°C, maximum.
Vibration: MIL-STD-202, method 204, test condition D.
Marking location: See figure 1.
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business