MIL-PRF-83446/7D
TABLE I. Electrical characteristics (initial) and dash numbers.
Incre-
Test
Q
Q
DC
Self
Inductance
Current
mental
Freq-
Typ
Min
resistance
Dash
resonant
(µH)
(max)
current
qency
at L
at L
at 25°C
number
frequency
mA
(max)
(MHz)
nom
nom
(max)
(min)
2/
mA
1/
ohms
MHz
Min
Nom
Max
3/
01, 48
0.016
0.018
0.019
50
60
150
1200
0.02
750
----
02, 49
0.019
0.022
0.024
50
60
150
1100
0.02
750
----
03, 50
0.024
0.027
0.029
50
60
150
1000
0.03
750
----
04, 51
0.029
0.033
0.036
50
59
150
900
0.03
750
----
05, 52
0.036
0.039
0.042
50
60
150
750
0.03
750
----
06, 53
0.042
0.047
0.051
50
59
100
660
0.04
750
----
07, 54
0.051
0.056
0.062
50
60
100
610
0.04
750
----
08, 55
0.061
0.068
0.074
50
58
100
550
0.05
750
----
09, 56
0.072
0.082
0.092
50
60
100
520
0.06
640
----
10, 57
0.091
0.100
0.114
50
58
50
490
0.07
600
----
11, 58
0.112
0.120
0.135
40
50
50
460
0.07
600
----
12, 59
0.130
0.15
0.165
40
50
50
430
0.10
480
----
13, 60
0.160
0.18
0.195
40
50
50
385
0.12
450
----
14, 61
0.195
0.22
0.245
40
51
50
330
0.15
400
----
15, 62
0.240
0.27
0.300
40
50
50
275
0.20
350
----
16, 63
0.295
0.33
0.365
40
50
50
240
0.25
300
----
17, 64
0.360
0.39
0.430
35
46
50
210
0.35
260
----
18, 65
0.425
0.47
0.515
35
42
25
190
0.40
250
----
19, 66
0.510
0.56
0.620
35
43
25
165
0.50
230
----
20, 67
0.610
0.68
0.750
35
42
25
155
0.75
180
----
21, 68
0.740
0.82
0.920
35
41
25
145
0.90
160
----
22, 69
0.900
1.0
1.10
35
42
25
130
1.8
120
----
23, 70
1.10
1.2
1.30
35
43
25
120
1.9
115
----
24, 71
1.35
1.5
1.65
22
33
7.9
105
3.0
90
----
25, 72
1.60
1.8
1.95
22
32
7.9
95
3.5
85
----
26, 73
1.95
2.2
2.45
19
25
7.9
85
6.5
62
----
27, 74
2.40
2.7
3.10
19
26
7.9
80
7.0
60
----
28, 75
3.00
3.3
3.65
15
24
7.9
75
7.5
55
----
29, 76
3.60
3.9
4.40
15
22
7.9
70
10.0
50
----
30, 77
4.30
4.7
5.20
15
26
7.9
38
2.5
100
----
31, 78
5.10
5.6
6.10
20
27
7.9
36
2.5
100
----
32, 79
6.10
6.8
7.35
20
28
7.9
35
3.5
85
----
33, 80
7.3
8.2
9.4
20
28
7.9
30
4.5
75
----
34, 81
9.0
10
11.0
20
28
7.9
25
5.0
70
----
35, 82
10.8
12
13.6
20
28
7.9
20
5.5
65
----
36, 83
13.4
15
16.8
20
30
2.5
18
6.5
60
----
37, 84
16.4
18
20.0
20
30
2.5
17
11.0
47
----
38, 85
19.6
22
25.5
20
30
2.5
16
12.0
45
----
39, 86
24.5
27
31.0
20
30
2.5
13
13.5
43
----
40, 87
30.0
33
38.0
20
30
2.5
11
14.0
42
----
41, 88
36.0
39
44.0
20
30
2.5
10
18.0
37
7.5
42, 89
42.0
47
53.0
20
30
2.5
9
20.0
35
7.0
43, 90
50.0
56
64.0
20
30
2.5
8
22.0
34
6.8
44, 91
60.0
68
76.0
20
30
2.5
7
24.0
32
6.4
45, 92
72.0
82
94.0
20
30
2.5
6
38.0
25
5.0
46, 93
90.0
100
115.0
20
28
2.5
5.2
42.0
24
4.8
47, 94
110.0
120
140.0
20
28
2.5
5.0
52.0
22
4.5
1/ Test frequency range 2.5 through 25 MHz: For electrical characteristics measurements, use the TF-260Q-1 test
fixture, or equivalent (see figure 3). Fixture inductance (approximately 0.028 µH) and residual Q-meter
inductance (approximately 0.01 µH) should be subtracted from indicated inductance.
Test frequency range 25 through 150 MHz: For electrical characteristics measurements, use the TF-250RX-1
test fixture, or equivalent (see figure 2). Fixture inductance (approximately 0.009 µH) should be subtracted from
indicated inductance.