MIL-PRF-83446/8E
TABLE I. Electrical characteristics (initial) and dash numbers.
Self
Test
Current
DC
Inductance
Q
Q
Dash
resonant
Frequency
(max)
resistance
±10%
(typ)
(min)
number
frequency
(MHz)
mA
(max)
(µH)
(min)
1/
2/
ohms
MHz
30, 79
2.70
41
48
7.90
80
1.7
125
31, 80
3.30
42
50
7.90
75
1.8
120
32, 81
3.90
42
50
7.90
65
2.0
110
33, 82
4.70
41
48
7.90
55
2.3
100
34, 83
5.60
41
48
7.90
45
2.6
98
35, 84
6.80
36
43
7.90
40
2.8
94
36, 85
8.20
36
43
7.90
35
3.0
90
37, 86
10.0
36
43
7.90
33
3.3
87
38, 87
12.0
36
43
7.90
26
4.0
79
39, 88
15.0
32
38
2.50
24
4.2
79
40, 89
18.0
32
38
2.50
21
4.4
75
41, 90
22.0
32
38
2.50
19
7.5
57
42, 91
27.0
32
38
2.50
14
8.0
55
43, 92
33.0
30
35
2.50
12
13.0
45
44, 93
39.0
30
35
2.50
10
17.0
38
45, 94
47.0
30
35
2.50
9.0
19.0
36
46, 95
56.0
30
35
2.50
8.5
23.0
33
47, 96
68.0
30
35
2.50
8.2
25.0
32
48, 97
82.0
30
35
2.50
8.0
28.0
30
49, 98
100.0
30
35
2.50
7.0
31.0
28
1/ Test frequency range 0.25 through 25 MHz: For electrical characteristics measurements, use the TF-260Q-1 test
fixture, or equivalent (see figure 3). Fixture inductance (approximately 0.028 µH) and residual Q-meter
inductance (approximately 0.01 µH) should be subtracted from indicated inductance.
Test frequency range 25 through 150 MHz: For electrical characteristics measurements, use the TF-250RX-1
test fixture, or equivalent (see figure 2). Fixture inductance (approximately 0.009 µH) should be subtracted from
indicated inductance.
2/ Maximum current allowed is not to exceed the specified temperature rise.
5
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business