MIL-T-27/176B
Rated load:
With 35 ohms, 10 kilohertz across (1-2). Current in (3-5): 70 milliamperes.
Voltage across (3-5): 10 volts ct.
Polarity: Additive with terminals 2 and 3 connected. Vibration, low frequency: MIL-STD-202, method 201.
Shock (specified pulse): MIL-STD-202, method 213, test condition I. VERIFICATION:
Qualification inspection: Not applicable.
Conformance inspection: Groups A and B tests of MIL-PRF-27 shall be applicable. Marking location: See figure 1.
Part or Identifying Number (PIN): M27/176-01.
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue.
Referenced documents. In addition to MIL-PRF-27, this document references the following: MIL-STD-202
Custodians: Preparing activity: Army - CR DLA - CC
Navy - EC
Air Force - 85 (Project 5950-2009-078) DLA - CC
Review Activities:
Army - AR, CR4, MI Navy - AS, MC, OS, SH Air Force - 19, 99
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.daps.dla.mil.
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business