Unbalance (5-7) and (7-9): 2 percent maximum. Unbalance (6-7) and (7-8): 2 percent maximum. Voltage across (10-11): 5.5 V maximum.
Voltage across (10-12): 6.89 V maximum. Voltage across (13-14): 7.01 V maximum. Voltage across (1-2): 105 V ±1 percent. Voltage across (1-4): 125 V ±1 percent.
Rated load: With 105 V, 60 Hz across (1-2) and (5-9) loaded with 5R4WGB full wave rectifier and 0.070 ampere dc
into 7.5 H inductive input filter and rated current in (10-12) and (13-14): Voltage across (5-9): 400 V ±4 percent.
Voltage across (10-12): 6.3 V ±2 percent. Voltage across (13-14): 6.3 V ±2 percent.
Electrostatic shielding: Voltage ratio: 5 to 1 at 20 kHz.
Polarity: Additive, with terminals 4 and 5; 9 and 10; and 12 and 13 connected.
Temperature rise: +40°C with 105 V, 54 Hz across (1-2) and (5-9) loaded with 5R4WGB full wave rectifier and 0.070 ampere dc into 7.5 H inductive input filter and rated current in (10-12) and (13-14) at an ambient temperature of
+65°C. VERIFICATION:
Qualification inspection: Not applicable.
Conformance inspection: Groups A and B tests of MIL-PRF-27 shall be applicable. Marking location: See figure 1.
Part or Identifying Number (PIN): M27/36-01.
NOTE: Transformers covered by this specification sheet are substitutable for transformers, MS part number
MS90026-2.