MS14041B
TABLE I. Electrical characteristics (initial).
Dash number 1/ |
Type designation 2/ |
Superseded MS PIN |
Inductance (µH) ±10% |
Q (min) |
Test frequency (MHz) |
SRF min (MHz) |
DC resistance (ohms) |
Rated dc current (mA) |
-1 -2 -3 -4 -5 |
LT10K108 LT10K109 LT10K110 LT10K111 LT10K112 |
MS18100-23 MS18100-24 MS18100-25 MS18100-26 MS18100-27 |
68 82 100 120 150 |
45 40 35 60 60 |
2.5 2.5 2.5 .79 .79 |
6.8 6.3 5.8 5.0 4.4 |
3.3 3.5 3.8 4.7 5.3 |
165 157 152 138 132 |
1/ The dash number added to MS military standard number constitutes the MS PIN; for example MS14041-1.
2/ The decrease in maximum operating temperature from 125°C to 105°C does not downgrade these coils but assures satisfactory operation at 105°C for a minimum of 2,000 hours of life rather than a shorter period of operation at 125°C.
TABLE II. Electrical characteristics (final). 1/
Inspection group |
Allowable variation from Initial measurement |
Allowable percent from specified minimum value in electrical characteristics (initial) table |
||
Inductance (percent) |
DC resistance |
Self-resonant frequency |
Q |
|
Qualification inspection Group II Group III Group IV 2/ |
±2 ±5 ±5 |
--- ±(3% +.001 ohm) ±(2% +.001 ohm) |
--- -8 -10 |
-10 -10 -15 |
Conformance inspection group C Subgroup I Subgroup II 2/ Subgroup III |
±2 ±5 ±5 |
--- ±(2% +.001 ohm) ±(3% +.001 ohm) |
--- -10 -8 |
-10 -15 -10 |
1/ Test fixture allowance of +.01 µH shall be added to all change in inductance limits ±( _ percent +.01 µH).
2/ The polarizing voltage during the moisture resistance tests Is applied with the positive lead connected to the coil terminals tied together, and the negative lead connected to the metal strap.
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business