MS21363B
TABLE II. Electrical characteristics (final). 1/
Inspection group |
Allowable variation from Initial measurement |
Allowable percent from specified minimum value in electrical characteristics (initial) table |
||
Inductance (percent) |
DC resistance |
Self-resonant frequency |
Q |
|
Qualification inspection Group II Group III Group IV |
±5 ±10 ±5 |
--- ±(5% +.001 ohm) ±(2% +.001 ohm) |
--- -15 -5 |
-10 -20 -20 |
Conformance inspection group C Subgroup I Subgroup II 2/ Subgroup III |
±5 ±5 ±10 |
--- ±(2% +.001 ohm) ±(5% +.001 ohm) |
--- -5 -15 |
-10 -20 -20 |
1/ Test fixture allowance of +.01 µH shall be added to all change in inductance limits ±( _ percent +.01 µH).
NOTES:
1. After the overload test is performed, a period of 24 hours shall elapse prior to taking electrical characteristics
(final) measurements.
2. DC resistance shall be the last measurement taken in the electrical characteristics test sequence.
4