MS21367G
TABLE II. Electrical characteristics (final). (For .015 μH through 1.0 μH) 1/
Inspection group |
Allowable variation from Initial measurement |
Allowable percent from specified minimum value in electrical characteristics (initial) table |
||
Inductance (percent) |
DC resistance |
Self-resonant frequency |
Q |
|
Qualification inspection Group II Group III Group IV |
±5 ±10 ±5 |
--- ±(3% +.001 ohm) ±(2% +.001 ohm) |
--- -10 -10 |
-10 -15 -10 |
Conformance inspection group C Subgroup I Subgroup II Subgroup III |
±5 ±5 ±10 |
--- ±(2% +.001 ohm) ±(3% +.001 ohm) |
--- -10 -10 |
-10 -10 -15 |
TABLE III. Electrical characteristics (final). (For 1.2 μH through 10 μH) 1/
Inspection group |
Allowable variation from Initial measurement |
Allowable percent from specified minimum value in electrical characteristics (initial) table |
||
Inductance (percent) |
DC resistance |
Self-resonant frequency |
Q |
|
Qualification inspection Group II Group III Group IV |
±2 ±5 ±2 |
--- ±(3% +.001 ohm) ±(2% +.001 ohm) |
--- -8 -10 |
-10 -10 -10 |
Conformance inspection group C Subgroup I Subgroup II Subgroup III |
±2 ±2 ±5 |
--- ±(2% +.001 ohm) ±(3% +.001 ohm) |
--- -10 -8 |
-10 -10 -10 |
1/ The test fixture in the diagram below or its equivalent shall be used for electrical measurements. Inductance values are effective inductance as indicated on a HP260A or equivalent, Q meter, when tested in the test fixture. Inductance of 10 μH or less are corrected for residual meter and test fixture inductance which is typically