MS90539D
TABLE 1. Electrical characteristics (initial).
Dash Number MS90539 1/ |
Type Designa- tion |
Inductance (µH) ±5% |
Q (min) |
Test Frequency (MHz) |
SRF Minimum (MHz) |
DC resistance Max. (ohms) |
Rated DC current (mA) |
-01 -02 -03 -04 -05 -06 -07 -08 -09 -10 -11 -12 -13 -14 -15 |
LT10K022 LT10K023 LT10K024 LT10K025 LT10K026 LT10K027 LT10K028 LT10K029 LT10K030 LT10K031 LT10K032 LT10K033 LT10K034 LT10K035 LT10K036 |
270 300 330 360 390 430 470 510 560 620 680 750 820 910 1000 |
65 65 65 65 65 65 65 65 65 60 60 60 60 60 60 |
.79 .79 .79 .79 .79 .79 .79 .79 .79 .79 .79 .79 .79 .79 .79 |
5.6 5.3 5.0 4.7 4.5 4.3 4.0 3.8 3.6 3.5 3.4 3.3 3.1 2.9 2.24 |
8.2 8.7 9.1 9.6 10.0 10.6 11.1 11.6 12.3 13.0 13.7 14.4 15.1 15.8 16.5 |
110 107 105 102 100 97 95 93 91 88 85 83 81 79 78 |
1/ The polarizing voltage during the moisture resistance tests is applied with the positive lead connected to the coil terminals tied together, and the negative lead connected to the metal strap.
TABLE II. Electrical characteristics (final).
Inspection group |
Allowable variation from Initial measurement |
Allowable percent from specified minimum value in electrical characteristics (initial) table |
||
Inductance (percent) |
DC resistance |
Self-resonant frequency |
Q |
|
Qualification inspection Group II Group III Group IV |
±2 ±5 ±5 |
--- ±(3% +.001 ohm) ±(2% +.001 ohm) |
--- -8 -10 |
-10 -10 -15 |
Conformance inspection group C Subgroup I Subgroup II Subgroup III |
±2 ±5 ±5 |
--- ±(2% +.001 ohm) ±(3% +.001 ohm) |
--- -10 -8 |
-10 -15 -10 |
3
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business