TABLE I. Electrical ratings - Continued. 4/
Primary 1/
Secondary 1/
Primary
Secondary
Power
Primary
Working
Dielectric withstanding
Impedance
Impedance
DCR
DCR
Level
dc
voltage
voltage 2/
Terminal
Circuit
Dash
(ohms)
(ohms)
±25%
±25%
(mW)
current
(volts)
Sea
Reduced
arrangement
diagram
No.
(ohms)
(ohms)
(mA)
level
Barometric
(see figure 2)
(see figure 3)
pressure
14
10 k
1M
330
4875
10
0
175
500
300
A
1
15
15 k
60 k
690
3100
4
0
175
500
300
A
1
16
15 k
60 k
690
3100
25
175
500
300
D
1
17
15 k
95 k CT
673
3800
2
0
175
500
300
I
3
15 k
95 k
1260
5800
12
4
175
500
300
B
4
18
SPLIT
20 k CT
600/150
930
45
125
4
175
500
300
J
5
19
SPLIT
1/ Impedance values written one above the other indicate a range of matching impedances over which the parts will give satisfactory performance as long
as the impedance ratio is maintained.
2/ Dielectric withstanding voltage between split sections, 50 volts rms maximum.
3/ 250 mW at 100 Hz, 1 watt at 200 Hz.
4/ Qualification testing and approval to M27/166-01 shall be sufficient to grant qualification approval to M27/166-02 through M27/166-19, inclusive.