MIL-PRF-27/341E
Regulation: Voltage (no load ) Voltage (rated load )
x 100
Voltage (rated load )
Shall not exceed 10 percent.
Polarity: Additive with terminals 2 and 3 connected.
Marking location: See figure 1.
Part or Identifying Number (PIN): M27/341-(dash number from table I).
TABLE I. Electrical ratings.
Secondary
Secondary
Secondary
current
DCR
Dash
voltage
(3-5)
(3-5)
number
(3-5)
(ohms) 25%
(V rms) 5%
(amperes)
M27/341-
(CT)
01
5.0
4.8
.037
02
6.3
3.8
.057
03
8.0
3.0
.091
04
10.0
2.4
.140
05
12.6
1.9
.175
06
14.0
1.7
.26
07
16.0
1.5
.38
08
18.0
1.33
.44
09
20.0
1.2
.48
10
22.0
1.09
.63
11
25.0
0.96
.73
12
28.0
0.855
1.07
13
31.0
0.772
1.5
14
35.0
0.685
1.7
15
39.0
0.615
2.4
16
43.0
0.556
2.6
17
48.0
0.500
3.6
18
55.0
0.435
3.83
19
63.0
0.380
6.0
20
70.0
0.342
6.8
21
80.0
0.300
9.6
22
90.0
0.267
13.8
23
100.0
0.240
14.4
24
110.0
0.218
19.5
25
123.0
0.195
21.9
26
138.0
0.174
30.3
27
157.0
0.152
36.1
28
175.0
0.136
49.5
29
200.0
0.120
57.0
30
220.0
0.109
79.0
31
26.0
0.923
0.71
32
115.0
0.209
20.40