MIL-PRF-27/96A
REQUIREMENTS:
Electrical ratings:
Primary power level: 100 mW.
Working voltage: 49 volts, maximum.
Primary current: 2 mA dc.
Primary impedance: (BLU-RED) 1,200 ohms.
Secondary load impedance: (BLK-GRN) 3.2 ohms.
Design and construction:
Dimensions and configuration: See figure 1.
Duty cycle: Continuous.
Terminals: Solder wire, insulated.
Material: Insulated type D, in accordance with MIL-STD-1276.
Diameter: .016 inch (0.41 mm).
Length: 1.500 ±.250 inch (38.1 ± 6.35 mm).
Weight: 3.5 grams.
Altitude: 70,000 feet, maximum.
Operating temperature range: -55°C to +105°C.
Terminal strength: MIL-STD-202, method 211, test condition A, 2 pounds.
Dielectric withstanding voltage:
At sea level): 100 volts rms.
At reduced barometric pressure: 100 volts rms.
Electrical characteristics:
Primary impedance: (BLU-RED) 1200 ohms with approximately 11 volts, 1 kHz and 2 mA dc applied to
(BLU-RED) and 3.2 ohms across (BLK-GRN).
Harmonic distortion: Total harmonic content of output 5 percent with 11 volts, 1 kHz and 2 mA dc applied
to (BLU-RED).
Frequency response: ZS=1200 ohms (BLU-RED), ZL=3.2 ohms (BLK-GRN), ES=2.5 volts, reference
frequency = 1 kHz, frequency range = 300 Hz to 20 kHz ±3 dB.
Polarity: Additive, with terminals RED and BLK connected.
Vibration (high frequency): MIL-STD-202, method 204, test condition B