MIL-PRF-83446/14B
TABLE I. Electrical characteristics (initial).
Self
Current
DC
Test
Inductance
resonant
Q
Q
Incremental
Dash
(max)
resistance
Frequency
±10%
frequency
(min)
(typ)
current
number
mA
(max)
(MHz)
(µH)
(min)
3/
2/
ohms
1/
MHz
30
2.7
32
45
7.90
85
3.65
175
----
31
3.3
32
50
7.90
70
4.00
170
----
32
3.9
32
50
7.90
60
2.10
165
----
33
4.7
32
45
7.90
50
2.30
165
----
34
5.6
35
45
7.90
40
2.30
165
----
35
6.8
43
50
7.90
30
1.30
165
----
36
8.2
40
45
7.90
22
4.00
120
----
37
10.0
40
45
7.90
20
2.90
105
58
38
12.0
35
45
2.50
15
3.50
91
53
39
15.0
35
40
2.50
13
2.30
87
50
40
18.0
35
45
2.50
12
3.70
81
46
41
22.0
35
45
2.50
10
4.00
77
37
42
27.0
38
45
2.50
9.0
5.00
73
34
43
33.0
35
45
2.50
9.0
5.70
69
32
44
39.0
35
45
2.50
6.5
6.50
65
29
45
47.0
35
45
2.50
6.2
6.00
63
29
46
56.0
35
40
2.50
6.0
6.30
60
28
47
68.0
30
45
2.50
5.8
6.70
57
26
48
82.0
35
45
2.50
5.2
7.50
55
23
49
100
33
40
2.50
4.0
13.0
50
20
50
120
33
40
0.790
4.0
14.0
40
20
51
150
35
40
0.790
3.9
16.0
36
20
52
180
35
40
0.790
3.5
18.0
33
19
53
220
35
40
0.790
3.2
21.0
28
18
54
270
35
40
0.790
3.1
23.0
25
17
55
330
35
40
0.790
2.8
37.0
20
16
56
390
35
40
0.790
2.5
39.0
17
16
57
470
35
40
0.790
2.3
45.0
15
15
58
560
35
40
0.790
2.2
47.0
13
14
59
680
35
40
0.790
2.1
62.0
12
13
60
820
35
40
0.790
2.1
78.0
11
11
61
1000
33
40
0.790
1.1
96.0
10
10
1/ Test frequency range 0.25 through 25 MHz: For electrical characteristics measurements, use the HP260-A
Q Meter, HP4342A, HP250B RX Meter, or equivalent with the TF-405 test fixture, or equivalent (see figure 2).
Fixture inductance (approximately 0.038 µH) and residual Q-meter inductance (approximately 0.01 µH) should be
subtracted from indicated inductance.
Test frequency range 25 through 150 MHz: For electrical characteristics measurements, use the HP190-A
Q Meter, HP260-A Q Meter, HP4342A, HP250B RX Meter, or equivalent with the TF-405 test fixture, or equivalent
(see figure 2). Fixture inductance (approximately 0.009 µH) should be subtracted from indicated inductance.
2/ Maximum current allowed is not to exceed the specified temperature rise.
3/ Applicable to ferrite core only.
4
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business