MIL-T-27/748
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for general information only.
3. Unless otherwise specified, tolerance is ±.016 (0.41 mm).
4. Marking shall be on sides or top of case.
FIGURE 1. Dimensions and configuration - Continued.
REQUIREMENTS: (When numbers in parentheses, i.e., (1-3) are used, they indicate the winding and the extreme terminals of the winding.)
Electrical ratings: See table I.
Primary power level: 10 mW maximum. Working voltage : 30 volts.
Primary current: Zero.
Primary impedance (1-2): 100 kilohms. Design and construction:
Dimensions and configuration: See figure 1. Duty cycle: Continuous.
Altitude: 10,000 feet. Terminals: Wire hook.
Diameter: 0.175 inch.
Length: 0.500 inch maximum. Weight: 0.2 pound.
Operating temperature range: -55°C to +105°C.
Terminal strength: MIL-STD-202, method 211, test condition A, 2 pounds. Dielectric withstanding voltage (at sea level): 500 V rms.
Electrical characteristics: See table II.
No load (centertap voltage unbalance only): With 5 V, 1 kHz applied to (1-2); unbalance (3-4) and
(4-5) ±1 percent maximum.
Harmonic distortion: Total harmonic content of the output: 5% with 5 V, 400 Hz applied to (1-2) maximum.
2
For Parts Inquires submit RFQ to Parts Hangar, Inc.
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business