MIL-T-27/74B
Primary impedance: 100 kilohms with approximately 5 V, 400 Hz applied to (1-2) and 50 kilohms across (3-5). Frequency response:
ZS = 100 kilohms (1-2) ZL = 50 kilohms (3-5) ES = 5 V
Reference frequency = 1 kHz.
Frequency range is 100 to 10,000 Hz ±2 dB.
Insertion loss: 1 dB with 10 mW, 400 Hz across (1-2) maximum.. Resonance: Second resonant frequency - 20 kHz minimum. Electrostatic shielding: Voltage ratio, 5:1 minimum at 20 kHz. Polarity: Additive, with terminals 2 and 3 connected.
VERIFICATION
Qualification inspection: Not applicable.
Conformance inspection: Groups A and B tests of MIL-PRF-27 shall be applicable. Marking location: See figure 1.
Part or Identifying Number (PIN): M27/74-01.
Changes from previous issue. The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the last previous issue.
Referenced documents. In addition to MIL-PRF-27, this document references the following:
MIL-STD-202
Custodians: Preparing activity: Army - CR DLA - CC
Navy - EC
Air Force - 85 (Project 5950-2009-073) DLA - CC
Review activities: Army - AR, CR4, MI Navy - AS, MC, OS, SH Air Force - 19
NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of this information above using the ASSIST Online database at https://assist.daps.dla.mil.