TABLE I. Electrical characteristics (initial) and dash numbers.
Self
Test
Current
DC
Incremental
Inductance
Q
Q
Dash
resonant
Frequency
(max)
resistance
Current
±10%
(typ)
(min)
number
frequency
(MHz)
mA
(max)
mA
(µH)
(min)
1/
2/
ohms
3/
MHz
30
2.7
32
45
7.90
85
3.65
175
----
31
3.3
32
50
7.90
70
4.00
170
----
32
3.9
32
50
7.90
60
2.10
165
----
33
4.7
32
45
7.90
50
2.30
165
----
34
5.6
35
45
7.90
40
230
165
----
35
6.8
43
50
7.90
30
1.30
165
----
36
8.2
40
45
7.90
22
4.00
120
----
37
10
40
45
7.90
20
2.90
105
58
38
12
35
45
2.50
15
3.50
91
53
39
15
35
40
2.50
13
2.30
87
50
40
18
35
45
2.50
12
3.70
81
46
41
22
35
45
2.50
10
4.00
77
37
42
27
38
45
2.50
9.0
5.00
73
34
43
33
35
45
2.50
9.0
5.70
69
32
44
39
35
45
2.50
6.5
6.50
65
29
45
47
35
45
2.50
6.2
6.00
63
29
46
56
35
40
2.50
6.0
6.30
60
28
47
68
30
45
2.50
5.8
6.70
57
26
48
82
35
45
2.50
5.2
7.50
55
23
49
100
33
40
2.50
4.0
13.0
50
2
50
120
33
40
0.790
4.0
14.0
40
20
51
150
35
40
0.790
3.9
16.0
36
20
52
180
35
40
0.790
3.5
18.0
33
19
53
220
35
40
0.790
3.2
21.0
28
18
54
270
35
40
0.790
3.1
23.0
25
17
55
330
35
40
0.790
2.8
37.0
20
16
56
390
35
40
0.790
2.5
39.0
17
16
57
470
35
40
0.790
2.3
45.0
15
15
58
560
35
40
0.790
2.2
47.0
13
14
59
680
35
40
0.790
2.1
62.0
12
13
60
820
35
40
0.790
2.1
78.0
11
11
61
1000
33
40
0.790
1.1
96.0
10
10
1/ Test frequency range 0.25 through 25 MHz: For electrical characteristics measurements, use the HP260-A
Q Meter, HP4342A, HP250B RX Meter or equivalent with TF-301 test fixture, or equivalent (see figure 2). Fixture
inductance (approximately 0.038 µH) and residual Q-meter inductance (approximately 0.01 µH) should be
subtracted from indicated inductance.
Test frequency range 25 through 200 MHz: For electrical characteristics measurements, use the HP190-A
Q Meter, HP260-A Q Meter, HP4342A, HP250B RX Meter or equivalent with TF-301 test fixture, or equivalent
(see figure 2). Fixture inductance (approximately 0.009 µH) should be subtracted from indicated inductance.
2/ Maximum current allowed is not to exceed the specified temperature rise.
3/ Applicable to ferrite core only.
4