n. Same processing material and specification for case, finish and marking.
o. Same processing material and composition for potting, insulation (tapes and films), impregnation, staking and filling.
p. Same material composition, characteristic and coating for the ferrite and MMP core, same shape, and the same manufacturer.
q. Same bobbin material and characteristics. r. Same solder composition and welding.
s. Same construction and material for the terminals. For terminals of the same dimensions the required terminal strength requirements to be the same or lower.
5.6.6.2.2 Inspection requirements. Transformers and inductors shall be subjected to and pass the applicable quality conformance inspection requirements of 5.6.7.
5.6.7 Quality conformance inspection.
5.6.7.1 Inspection of product for delivery.
5.6.7.1.1 Class S devices. Inspection of product for delivery shall consist of the applicable group A screening tests (see 5.6.7.3.3 through 5.6.7.3.9.2) and the applicable group B tests (see tables XI through XV). Sample size for group B tests shall be as specified under the sampling plan (see 5.6.7.4.1.2).
5.6.7.1.2 Class B devices. Inspection of product for delivery shall consist of the applicable group A screening tests (see 5.6.7.3.3 through 5.6.7.3.9.2). A device to be qualified by similarity shall be subjected to the tests specified in TABLE IV. Samples of each part type shall be selected at random from the inspection lot which has passed the group A tests.